Therm-A-Stop is
a new generation of combined fire and smoke seal, designed for
use in fire door assemblies which are required to control the
spread of smoke and flame during a fire. The casings contain
an expandable graphite-based intumescent compound which unlike
some products, is unaffected by moisture in the air and so does
not require to be carefully protected when being fitted. The
brush piles include a thin polypropylene fin to reduce the flow
of ambient smoke. The seals are rebated into the head and jambs.
Therm-A-Stop
Seals are suitable for
FD20S, FD30S and FD60S single
and double doorsets in timber, steel (or both).
Single action and double swing doorsets (latched or unlatched).
Controlling the flow of ambient temperature smoke during the
early stages of a fire.
Therm-A-Stop is available in brown, white, cream
and red casings as standard with grey pile which projects 5mm
beyond the casing which is sufficient for most leaf-frame gaps
although an alternative is available for larger gaps. Therm-A-Stop is supplied in standard lengths of 1050mm
and 2100mm (with or without double-sided self-adhesive tape on
the underside of the PVC casing). The casings are available in
the following nominal dimensions: 10 x 4mm, 15 x 4mm, 20 x 4mm,
25 x 4mm, 30 x 4 mm, 38 x 4mm, 10 x 5mm and 20 x 5mm.
Therm-A-Stop Seals meet the requirements of BS 5588
'Fire Precautions in the design and construction of buildings'
and have passed numerous tests carried out in accordance with
BS 476 : parts 20, 22 & 31.1 (details are available on request).
| Typical
Applications |
Latched single-leaf, single-swing
30 minute (FD30S) timber fire doors:
Single length of Therm-A-Stop 10 x 4mm or 10 x 5mm down each
jamb & across the head. |
Un-latched single-leaf, single or double-swing
30 minute (FD30S) timber fire doors:
Single length of Therm-A-Stop 10 x 4mm or 10 x 5mm down each
jamb & depending on the door a wider section may be required
across the head. |
Latched single-leaf, single-swing 60 minute
(FD60S) timber fire doors:
Single length of Therm-A-Stop 20 x 4mm or 20 x 5mm down each
jamb & across the head. Un-latched doors may require additional
protection across the head. |
|

|