Therm-A-Channel has been approved for use in FD30 and FD30S fire doors and screens incorporating panes of clear or wired fire safety glass up to 700mm x 800mm. It is placed like a gasket around the edge of each pane of glass and held discretely in place by the beads. No adhesives, sealants, treatments to the beads or other unsightly coatings are required. Therm-A-Channel is supplied ex-stock in coils of 100m or in increments of 10m in natural black finish. Therm-A-Channel has passed numerous tests carried out in accordance with BS 476 : parts 20 & 22 (1987). Details are available on request. Important: As with all such products, constructions incorporating Therm-A-Channel must follow one of the model specifications proven under test (details of the options for glass, beads, fixings etc for doors or screens are available in our literature and from our Technical Department). |
|
|||